RUIJIE RG-S6510-48VS8CQ

RUIJIE RG-S6510-48VS8CQ

Description

The RG-S6500 Series is a powerful collection of line-rate switches customized to power the next-generation data centers and cloud computing. Within 1RU configuration, RG-S6510-48VS8CQ  supports 48 x 25G ports and 8 x 100G ports offering line-rate forwarding from all ports.

The switches employ an advanced cache scheduling mechanism to maximize the device’s cache capability, ensuring truly non-blocking transmission in the increasingly demanding data center environment.

Data Center Virtualization

The RG-S6500 Series adopts the industry-leading Virtual Switch Unit(VSU) technology to achieve unified network management, reduce network nodes and enhance network reliability. The failover time for link failure is within 50 to 200ms to guarantee uninterrupted operation for mission-critical applications. The cross-device link aggregation feature enables access to servers or switches to achieve active-active uplinks.

RDMA Lossless Infrastructure

The TCP/IP protocol stack brings the latency of tens of microseconds. The CPU usage of the server is high due to the TCP protocol stack processing. When the network bandwidth reaches 25 Gbit/s, about 50% of the CPU capability of most servers will be used to transmit data. Remote direct memory access (RDMA) is a direct memory access from the memory of one computer into that of another without involving either one’s operating system. RDMA technology reduces the data transmission latency on the server to less than 1 microsecond and the CPU usage of the server will less than 5%. With the technology related to RoCE(RDMA over Converged Ethernet) , the RG-S6500 Series permits high-throughput, low-latency networking, which is especially useful in massively parallel computer clusters.

Fabric-based Flow Visualization

The RG-S6500 Series realizes flow visualization on complicated multi-path and multi-node network. With each flow’s path and latency centralized monitored, operators can locate the faults much more efficient.

Carrier-Class Reliability Protection

The RG-S6500 Series supports built-in redundant power modules and modularized fan components. All the interface boards, power modules, and fan modules are hot-pluggable to guarantee undisturbed switching operation. In addition, the switches support fault detection and automatic alarms for the power and fan modules. The rotation speed of the fans automatically adjusts to the ambient temperature. The switches further provide device-level and link-level reliability protection with the over-current, over-voltage, and overheating protection measures.

The RG-S6500 Series also supports features like REUP (Rapid Ethernet Uplink Protection), Graceful Restart (GR) and Bidirectional Forwarding (BFD) mechanisms. All the features ensure the network convergence time is unaffected even when the network bears abundant services and heavy traffic, and therefore ensure normal operation.

IPv4/IPv6 Dual-Stack Multi-Layer Switching

The hardware of the RG-S6500 Series supports line-rate IPv4/IPv6 dual-stack multi-layer switching, and distinguishes and processes IPv4 and IPv6 protocol packets. The switches also support multiple tunneling technologies including manually configured tunnels, automatic tunnels, ISATAP tunnels and so on. The switches provide flexible IPv6 inter-network communication solutions to be realized according the requirement plan and status quo of the IPv6 networks. The switch series is also applicable to an IPv4-only or IPv6-only network, or a hybrid of IPv4 and IPv6 network, fulfilling the transition requirements from IPv4 to IPv6 network.

The series supports a wide range of IPv4 routing protocols including static routing, RIP, OSPF, and BGP4, which can be selected flexibly according to the network environment. The series also supports an abundant list of IPv6 routing protocols, such as static routing, RIPng, OSPFv3, and BGP4+, which can be selected flexibly either to upgrade the existing network to IPv6 network or to construct a new IPv6 network.

Flexible and Comprehensive Security Policies

The RG-S6500 Series features multiple security features, which effectively defend against and control virus flooding and hacker attacks. These features include anti-DoS attack, validity check of ARP packets on ports, and multiple hardware-based ACL policies.

The switches support hardware-based IPv6 ACLs, which can easily control IPv6 users’ access to edge devices even when IPv6 users exist within an IPv4 network. It allows coexistence of IPv4 and IPv6 users on the network and can control access permissions of IPv6 users, such as restricting access to sensitive resources on the network.

The switch series adopts Ruijie’s industry-leading CPU Protection Policy (CPP) technology, which is an advanced hardware-based CPU protection mechanism, to distinguish data traffic destined to the CPU and process data according to queue priorities. The switches implement bandwidth control to protect the CPU against unauthorized traffic consumption, malicious attacks and resource consumption and hence to ensure switch security. The hardware of the RG-S6500 Series allows flexible binding of a user IP address or a MAC address to a port or a switch to strictly control user access. The switches support DHCP snooping, which allows only a DHCP response to a trusted port to prevent spoofing by unauthorized DHCP servers. Based on DHCP snooping, the switches dynamically monitor ARP packets, check user IP addresses, and directly discard packets that do not comply with the bound entries. The RG-S6500 Series effectively defends against ARP spoofing and source IP address spoofing.

The switches also support Telnet access control based on source IP addresses. The measure prevents unauthorized users or hackers from attacking or controlling devices and thereby enhances security of the device NMS. The RG-S6500 Series also implement Secure Shell (SSH) and SNMPv3 to encrypt management information in Telnet and SNMP processes, thereby ensuring security of management device information and preventing hacker from waging attacks or controlling devices.

The series prevents unauthorized users from network access through multiple functions. These functions include multi-element binding, port security, time ACL, and bandwidth limit based on data traffic. The RG-S6500 Series highly strengthens access security and are perfect match for large-sized networks.

Advanced Management

The RG-S6500 Series supports a family of management ports such as Console, MGMT and USB. The switches also support SNMP v1/v2c/v3, a universal network management platform. In addition, the switch console port can be managed via Telnet / SSHv2, HTTP or HTTPS. The switches enable Command Line Interface (CLI), Telnet, and cluster management, which simplify device management and provide various encryption modes such as SSH2.0 to enhance network security.

The switches support SPAN/RSPAN mirroring and multiple mirroring observation ports, offering users high visibility and transparency for easy maintenance. The switches also provide a wide range of network traffic reports to help users optimize network structure and adjust resources deployment accordingly.

Model RG-S6510-48VS8CQ
Ports 48 fixed 25G SFP28 ports
8 100G QSFP28 ports
Modular Power Slots 2
Fan Slots 4
Management Ports 1 console port
1 MGMT port1 USB 2.0 port
Switching Capacity 4.0Tbps
Packet Forwarding Rate 2000Mpps
Port Buffer 32MB
RAM 4GB
ARP Table Up to 100K
MAC Address Up to 96K
Routing Table Size (IPv4/IPv6) Up to 28K
Multicast Entries (IPv4/IPv6) Up to 16K
ACL Entries Up to 4.5K
VLAN 4K VLANs, Port-based VLAN, MAC-based VLAN, Super VLAN, Protocol-based VLAN, Private VLAN, IP subnet-based VLAN, GVRP
QinQ Basic QinQ, Flexible QinQ
Link Aggregation Support LACP
Port Mirroring Many-to-one mirroring, One-to-many mirroring, Flow-based mirroring, Over devices mirroring, VLAN-based mirroring, VLAN-filtering mirroring, AP-port mirroring, RSPAN, ERSPAN
Spanning Tree Protocols IEEE802.1d STP, IEEE802.1w RSTP, Standard 802.1s MSTP, Port fast, BPDU filter, BPDU guard, TC guard, TC protection, Loop guard, Root guard,Spanning Tree Root Guard(STRG)
DHCP DHCP server, DHCP client, DHCP snooping, DHCP relay, IPv6 DHCP relay
Multiple Spanning Tree Protocol (MSTP) Instances 64 (not include default 0)
Maximum Aggregation Port (AP) Up to 256
Virtual Routing and Forwarding (VRF) Instances Up to 2K
Data Center Unified Network Features Virtualization:
Virtual Switch Unit (VSU), EVPN VXLAN, Open-Flow.Visualization:

INT, gRPC, s-FLOW,

Others:

PFC, ECN

VSU (Virtual Switch Unit) Support (up to 2 stack members)
L2 Features MAC, ARP, VLAN, Basic QinQ, Felix QinQ, Link aggregation, Mirroring, STP, RSTP, MSTP, Broadcast storm control, IGMP v1/v2/v3 snooping, IGMP filter, IGMP fast leave, MLD snooping, DHCP, Jumbo frame, RLDP, LLDP
Layer 2 Protocols IEEE802.3 (10BASE-T), IEEE802.3u (100BASE-T), IEEE802.3z (1000BASE-X), IEEE802.3ab (1000BASE-T), IEEE802.3ae (10GBASE-T), IEEE802.3an (10GBASE-T), IEEE802.3ak, IEEE802.3an, IEEE802.3x, IEEE802.3ad (link aggregation), IEEE802.1p, IEEE802.1x, IEEE802.1Q, IEEE802.1D (STP), IEEE802.1w (RSTP), IEEE802.1s (MSTP), IGMP snooping, Jumbo Frame (9Kbytes), IEEE802.1ad (QinQ and flexible QinQ), GVRP
Layer 3 Features ARP, IPv4/v6, PBRv4/v6
Layer 3 Protocols (IPv4) BGP4, OSPFv2, RIPv1, RIPv2, MBGP, LPM routing, Policy-based routing, Route-policy, ECMP, WCMP, VRRP, IGMP v1/v2/v3, DVMRP, PIM-SSM/SM/DM, MSDP, Any-RP, ISIS
IPv4 Features Ping, Traceroute, Equal-cost routing, URPF, IPIP, GRE tunnel, VRF
IPv6 Features Static routing Equal-cost routing, Policy-based routing, OSPFv3, RIPng, BGP4+, MLDv1/v2, PIM-SMv6, Manual tunnel, Auto tunnel, IPv4 over IPv6 tunnel, ISATAP tunnel
Basic IPv6 Protocols ND, ICMPv6, Path MTU Discovery, DNSv6, DHCPv6, ICMPv6, ICMPv6 redirection, ACLv6, TCP/UDP for IPv6, SNMP v6, Ping /Traceroute v6, IPv6 RADIUS, Telnet/SSH v6, FTP/TFTP v6, NTP v6, VRRP for IPv6, IS-ISv6
IPv6 Routing Protocols Static routing, Equal-cost routing, Policy routing, RIPng, OSPFv2/v3, BGP4+, IS-IS
IPv6 Tunnel Features Manual tunnel, Auto tunnel, 6over4 manual tunnel, 6to4 auto tunnel, ISATAP, IPv4 over IPv6 tunnel, IPv6 over IPv6 tunnel, GRE tunnel
Multicast IGMP v1/v2/v3, IGMP proxy, MSDP, PIM-DMv4 (PIM-DM), PIM-SMv4 (PIM-SM, PIM-SSM), PIM-SM v6, MLD, MLD Proxy
ACL Standard/Extended/Expert ACL, Extended MAC ACL, ACL 80, IPv6 ACL
QoS EXP priority mapping based on 802.1p, DSCP, TOS and IP Precedence; ACL traffic classification; Priority marking/remarking; Multiple queue scheduling mechanisms, such as SP, WRR, DRR, SP+WRR, and SP+DRR
Reliability VSU (virtualization technology for virtualizing multiple devices into 1); GR for OSPF/IS-IS/BGP; BFD detection; REUP dual-link fast switching technology; RLDP (Rapid Link Detection Protocol); 1+1 power redundancy; 2+1 fan redundancy; Hot-swappable line cards and power modules, Dynamic ARP Inspection(DAI),de-stacking
Security Network Foundation Protection Policy (NFPP); CPU Protection (CPP); DoS protection; Detection of unauthorized data packets; Data encryption; IP source guard; RADIUS / TACACS+; IPv4 / IPv6 ACL packet filtering based on standard or extended VLANs; Plaintext authentication and MD5 cipher-text authentication of OSPF, RIPv2, and BGPv4 packets; Telnet login through limited IP addresses and the password mechanism; u-RPF; Broadcast packet suppression; DHCP snooping, DHCP Option 82,; Anti-gateway ARP spoofing; ARP check,
Manageability SNMP v1/v2c/v3; Telnet; Console; Hardware support RCMI (combo interface for MGMT); RMON; SSHv1/v2; FTP/TFTP for file upload and download management; NTP clock; Syslog; SPAN/RSPAN,
Hot Patch Support
Smart Temperature Control Auto fan speed adjustment; Fan malfunction alerts; Fan status check
Smart Power Supply Support power monitor
Other Protocols DHCP client, DHCP relay, DHCP server, DNS client, UDP relay, ARP proxy, Syslog
Dimensions
(W x D x H) (mm)
442 * 387 * 44
Rack Height 1RU
Weight 8kg
(incl. 4 fan modules and 2 power supply modules)
MTBF 330K hours
Safety Standards EN 60950-1, GB4943-2011

 

Emission Standards GB9254-2008 CLASSA, VCCI Class A, EN 300 386, EN 55032, EN 61000-3-2, EN 61000-3-3, EN 55035, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11
Power Supply AC input:
Rated voltage range: 100V to 240V AC
Frequency: 50-60Hz
Rated current: 7.2A-3.5AHVDC input:
Input voltage range: 192V to 288V DC
Input current range: 3.6A
Power Consumption <300W
Temperature Operating temperature: 0°C to 45°C

Storage temperature: -40ºC to 70ºC

Humidity Operating humidity: 10% to 90%RH
Operating Altitude -500—5000 M
You've just added this product to the cart: